    Type: 05-089-2142-0. Code No.: 100-301-620-10. About the TFT LCD. The TFT LCD is constructed using the latest LCD techniques, and displaysBelow is the procedure for transmitting a distress alert via radiotelephone. Transmit the distressThe followingCountdown. The audio alarm sounds for two seconds. After the distress alert has been sent, the following screens appear in order.Press the CANCEL key to silence the audio alarm.Note: If you do not receive the distress alert acknowledge call, the equipment automatically retransmits the distress alert after 3 min 30 seconds to 4 min 30 seconds. Then awaits the distressThis is repeated until the distress alert is acknowledged.You can cancel the distress alert while it is being sent or while waiting for its acknowledgement asAfter transmitting the distress cancel call, the following message appears on the screen.The screen for the selection of frequency appears.The following messageThe screen for the selection of frequency appears again. The frequency marked by asterisk shows that the call cancellation by voice was completed for that frequency.When cancellation on all frequenciesResendSYSTEM CONFIGURATIONS. xiiiRadiotelephone (RT) Screen.1-2. DSC Scan Screen.1-3. How to Adjust the Brilliance of the Display and Panel.1-4. How to Scan.1-4. How to Set the Auto Acknowledgement.1-5. Control Unit Priority.1-5. Intercom.1-6. Operation of Session.1-7DSC Message.3-1. Audio Alarms.3-2. Description of Call Screens.3-3TX Message Preparation.6-16How to Set the AUTO ACK Details.6-21. Special Messages.6-22. How to Set Scan Frequencies.6-22. Sound Setting.6-23. Alarm Lists.6-24How to Open Files. 9-6How to Rename Files. 9-7. How to Save a File Under a New Name. 9-7. How to Delete Files. 9-8. Real Time Printing. 9-8. How to Print Files. 9-8ARQ Mode Operation. 10-3. FEC Mode Operation. 10-5. How to Select Reception Mode. 10-5. Communication Example. 10-6. Timer Operation. 10-8Maintenance. 11-3. Simple Troubleshooting. 11-4. Error Messages.

    • furuno ib-583 manual, furuno ib-583 manual, furuno ib-583 manual pdf, furuno ib-583 manual download, furuno ib-583 manuals, furuno ib-583 manual instructions.

    Nishinomiya, 662-8580, JAPAN. Fax. All rights reserved. Printed in Japan. Pub. No. OME-56770-Z4Wrong operation or maintenance can cancel the warranty or cause injury.The screens you see depend on your system configuration and equipment settings.How to discard this product. Discard this product according to local regulations for the disposal of industrial waste. For disposalHow to discard a used battery. Some FURUNO products have a battery(ies). To see if your product has a battery, see the chapterIn the European Union. The crossed-out trash can symbol indicates that all types of batteriesCd. In the USA. The Mobius loop symbol (three chasing arrows) indicates that Ni-CdNi-Cd. Pb. In the other countries. There are no international standards for the battery recycle symbol. The number of symbols canWarning, Caution. Prohibitive ActionSSB radiotelephone is transmitting. Immediately turn off the power atHigh voltage which will cause death orSSB radiotelephone is transmitting. Continued use of the equipment canIndoor. Antenna WireAntenna. Coupler. Antenna. Wire. Lead-in. InsulatorVoltage)Only qualified personnel should workImmediately turn off the power atContinued use of the equipment canMandatory Action. Do not place liquid-filled containersFire or electrical shock can result if aDo not operate the equipment withElectrical shock can result. Turn off the power immediately if youTurn off the power at the switchboard ifMake sure no rain or water splashFire or electrical shock can result ifDo not disassemble or modify theUse the proper fuse. Fire, electrical shock or serious injuryUse of the wrong fuse can cause fire orAccidental transmission may preventIf the distress alert is accidentallyDo not apply strong pressure toInjury can result if the LCD breaks.Do not remove any label. If a label is missing orName: Warning Label 1. Type: 86-003-1011-3. Code No.: 100-236-233-10. Name: Warning Label. Type: 14-055-4202-1. Code No.: 100-245-221-10. Name: High Temp Warning Label.

    Turns the squelch on or off in the RT mode. Reduces the noise in the RT mode (NR2 (High), NR1 (Low), Off). Turns the notch filter on or off in the RT mode. Tunes the antenna in radiotelephone operation.Lights in green when the main switchboard is on. The RT screen appears. In the dual control unit system, the No.1 control unit has priority and it controls theNote: Turn on the power at the switchboard more than five minutes before turning onThis is where you set up the transceiver unit, and communicate by voice or telex. Spinner: Rotates whenFunction keys. Tab area: SessionsRadiotelephone (RT) screenMeaning. Main speaker on or offRX frequency. Class of emission. S-meter, displays the strength of received signal. Noise blanker (Noise reduction (Own ship's ID (nine digits). Own ship's position (LAT: Latitude, LON: Longitude). UTC (universal time coordinated)Attenuator (Adjusted value of gain. DSC Scan Screen. Press the SCAN key to show the DSC scan screen. This screen scans and receivesRX: Transceiver unitMaximum six distress andPanel. You can adjust the brilliance of the display and the panel as follows:To cancel theNote 2: The window closes automatically when there is no operation for four seconds. Note 3: When you turn on the power with the display brilliance set to 0, the setting automatically changes to 1.Speaker ON. Speaker OFFThe DSC screen scans multiple routine frequencies according to operator-set interval. For how to set frequency to scan, see section 6.19. Note that voice and telex communication are not available when scanning.Scanning starts. When receiving the appropriate frequency signal, the scanning stops, and the frequencyNote: You can not stop the scanning manually for the distress alert.Note: When scanning starts, the active session (refer to section 1.11) is automaticallyIndividual, PSTN (public switched telephone network), position, polling and test callsNote: When own ship's communication is high priority, set to manual acknowledgement.

    11-4. Breaker on PR-850A. 11-5. Test Call. 11-5. NBDP Terminal Unit Maintenance. 11-6Since 1948, FURUNO Electric Company has enjoyed an enviable reputation for innovative andThis dedication to excellence is furthered by our extensive global network of agents and dealers. Your equipment is designed and constructed to meet the rigorous demands of the marine environment. However, no machine can perform its intended function unless properly installed andWe would appreciate feedback from you, the end-user, about whether we are achieving our purposes. Thank you for considering and purchasing FURUNO equipment. FeaturesAn NBDP (Narrow Band Direct Printing) Terminal. Unit is optionally available. Data is displayed on a large, easy-to-read color LCD. Operation is simplified by the use of fewThe main features are. GeneralProgram Number. Location. PC boardTerminal Unit IB-583 (optional unit). PC boardPC boardProgram No.VersionNo. 2 CONTROLPreamp Unit. Antenna Coupler. Other Units. Category. Exposed to the weather. Exposed to the weather ORProtected from the weatherControl. ENTER knob. PUSH TO ATT knob. DISTRESS key. MENU key. CANCEL key. TAB keyBRILL keyDISTRESS MSG key. DROBOSE MSG key. SCAN keyFunction. Rotate to select menu items or change the page in multi-page screens (e.g.,Rotate to adjust the gain; push to turn the attenuator on or off. Press and hold down the key four seconds to transmit the distress alert. Turns the main speaker on or off. Adjusts the brilliance. Composes DSC TX message except DISTRESS ALERT and DROBOSEComposes DSC TX message for DISTRESS ALERT. Composes DSC TX message for DROBOSE (Distress Relay On Behalf Of. Someone Else). Press the DISTRESS MSG key and the OTHER DSC. MSG key simultaneously.Switches to the RT (radiotelephone) screen and sets freq. to 2182.0 kHz. Enter alphabet, numeric or symbol. Execute the operation assigned to the function key in the RT mode.ALARM lamp. OVEN lampTurns the noise blanker on or off in the RT mode.

    If a seventh sessionPress the CANCEL key to closeIf the eighth session is for sending a distress alert, all sessions except that sessionYou can select the class of emission from among the following. Connect a FAX to this equipment to print FAX messages.). At the RT screen, select the class of emission as follows:This icon appearsAGC modeControl). Class ofChannel settingEnter channel with the numeric keys. Use the numeric keys to enter channel then push the ENTER knob. Select band and band channel with the ENTER knob:Cursor position for selection of bandITU band. Setting Range. User Band: 01-029 (First zero is necessary). ITU Channel (SSB): 00 - XX. ITU Channel (TLX): 000 - XXX. ITU Channel (CW): 001 - XXX. User Channel: 01 - 99FrequencyEnter frequency with the numeric keys. Use the numeric keys to enter frequency then push the ENTER knob. For example, to enter 2161 kHz, key in 2, 1, 6, 1, 0. (Note: Keying in 2-1-6-1 sets 216.1Select frequency with the ENTER knob (for RX only):Note: When TX and RX frequencies are different, first enter TX then enter RX.After selecting the class of emission and frequency, you can transmit by pressing the. PTT switch on the handset.Maximum transmission power is achieved only when the antenna impedance andBecause the antenna impedance changesThe antenna coupler automatically tunes the transmitter toThe available range is. To initiate the tuning, do the following:Tuning is automatically adjusted at firstIn this case, only the. DISTRESS key is operative on the idle control unit.To minimize possible interference to other stations, reduce the transmission power. This should be done when using the transceiver in a harbor, near the shore or closeNote: The temperature of the power amplifier is monitored. When its temperature rises above a certain temperature, output power is automatically reduced.Check the transmission power. During transmission, the IA bar deflects according to the current being fed from theThe unit of readout is amperes.

    The auto acknowledgement is not sent in the following cases. Note: The auto acknowledgement for the individual call is sent only when the proposed channel or communication mode is not available.If you operate the No.1 control unit while the No.2 control unit is being operated, theThe control unit which you operate has priority in the following conditions:The built-in intercom permits voice communications between two control units. Calling. You can call over the intercom in on or off hook condition.To cancel calling,Start communications. Note: You do not have to press the PTT switch to communicate.The lastused screen or the RT screen appears. AnsweringTo cancel reply, press the CANCEL key.The pop-up for calling disappears andStart communications.The lastused screen or the RT screen appears.Description of session. There are two types of sessions: RT session and DSC session. When a session starts,RT session. DSC sessions. Tab area. How to finish a single session. RT sessionStep 2: Rotate the ENTER. Step 1: Press the TAB keyDSC session. The cursor is in the tab area when the DSC session starts. Rotate the ENTER knob toWhen another session is active:When no other session is active:How to switch sessions. When one session is active and another message arrives, a new session for the received message does not start automatically. Only one session can be active. For example, when you are transmitting a DSC message and another message arrives, the. Press the TAB key to moveRX: 2182.00 kHzInformation for the sessionTab area. To select a session, press the. TAB key. The cursor is here.Note: When waiting for the ACK, that is, theHow to close a session. To manually close a session, select it with the TAB key. Rotate the ENTER knob to. The session icon disappears from the tab area. When there is no operation for specific time (see section 6.9), the inactive session isProcessing when the number of session is maximum. A maximum of seven sessions can be displayed in the tab area.

    Session in progressExamples:Below are sample distress alert and individual TX call screens. Nature of Distress. Position of ship in distress (yourCommunication mode. DSC frequency to send distress call. Individual TX call. Message typeID No. of stationCommunicationDSC frequencySafety, Urgency). CommunicationGMDSS ships carry a DSC terminal with which to transmit the distress alert in theA coast station receives the distress alert andThen, voice or telexTransmissionThere are three types of distress alerts; MULTI, SINGLE, AUTO. MULTI is used normally. To use another method, see step 10 in paragraph 4.1.2. Note: After sending the distress alert, no control unit has priority.The audio alarm sounds while pressing the key, and the key flashes in red. TheCountdown messageThe audio alarm soundsThe DISTRESS key lights inAfter the distress alert has been sent, the screen changes as below. Wait to receive the distress acknowledge call from a coast station. The elapsed time sinceAt this time, the icons for other DSC received messages except the distress alert acknowledge call are not displayed. You can only confirm them in the log. Elapsed timeTab area. Note: If you do not receive the distress alert acknowledge call, the equipment automatically re-transmits the distress alert after 3 min 30 seconds to 4 min 30 seconds. Then awaits the distress alert acknowledge call. This is repeated until theYou can temporarily stop the countdown for next retransmission by selecting. To restart, select. Also, you can re-send the distress alert manually by pressing the DISTRESS keyWhen the distress acknowledge call is received, the audio alarm sounds, the LEDThen, the LED stops flashing,Count up the elapsed timeIcon for DISTRESS transmittingIf you have a time to prepare the distress information, send the distress alert as follows:South (West for longitude).) Push the ENTER knob. Latitude setting window. Push the. Longitude setting window. UTC setting windowMHz.

    2 MHz and 8 MHz are automatically selected and cannot be excluded. Rotate the ENTER knob to select theAfter setting, rotate the ENTER knob toIf the distress alert is not acknowledged, transmission occurs in this sequence:The countdownFor NBDP, follow the procedure in “Communicating by NBDP terminal unit” on this page. For telephone, follow step 3 onCommunication by NBDP terminal unitCall Station. Station ListStation: DSC. ID Code. ModeRx Freq: 2174.50. For IB-585, these items are not displayedFor NBDP details, see chapters 7 through 10.When you receive a distress alert from a ship in distress, the audio alarm sounds andThe icon for DISTRESS receiving ( ) appears in the tab area. Press the CANCEL key to silence the audio alarm. Wait for the distress acknowledgeIf you do not receive the distress acknowledge call from aDo the following. Wait for coast station to acknowledge the distressDSC distress alert received. Press the CANCEL keyListen on 2182 kHzDid you receiveNo. Is distress trafficNo. Is the DSCYes. Yes. Is your shipNo. Acknowledge the alert by. Yes radiotelephone to the shipNo. Enter details in log. Send the distress acknowledge call to ship in distress (on MF band). Note: You must wait at least five minutes before you can acknowledge a distress alert,Transmit the distress acknowledge call to the ship in distress only when you do notFirst, contactWhen you receive a distress alert from a ship in distress, the audio alarm sounds andThe icon for DISTRESS receiving appears in the tab area andTo terminate transmission of the distress alert, send acknowledge call as follows.The screen changes as below.If you receive a distress alert on the HF band, the audio alarm sounds and the LEDPress the CANCEL key to silence the audio alarm and stop theWait for theIf you do not receive the distress acknowledge call from a coast station, which usually takes about five minutes from thePDF Version: 1.6. Linearized: Yes. Create Date: 2012:08:28 07:40:44-07:00.

    The antennaThe reading differs by the frequency and antenna length. The output power is proportional to the square of an antenna current. AntennaCheck if the class of emission and receiving frequency are set properly. If necessary,In normal use the sensitivity should be set for maximum. If the audio on the receivedThe setting value is displayed at the lower left-hand side of theThe S-meter shows relative signal strength coming into the receiver front end. S-meterThe noise blanker removes pulse noise.When the noise blanker function is active,The noise reduction circuit analyzes speech component and noise component, andEach time youNotch filter. The notch filter removes mixed CW (continuous wave) or beat signal interference. When the notch filter function is active,Squelch. The squelch mutes the audio output in the absence of an incoming signal. Press the. When radio noiseWhen the squelch function is active,Squelch frequency. To adjust the squelch frequency, see section 6.4.The attenuator reduces total gain and prevents saturation. TO ATT knob on the RT screen to turn the attenuator on and off alternately. When theUser ChannelsSee section 6.2 for the procedure.DSC is an acronym meaning Digital Selective Calling. It is a digital distress and general calling system in the MF and HF bands used by ships for transmitting distressFor DSC distress, safety and urgency callings in the MF and HF bands, the frequencies are 2187.5, 4207.5, 6312.0, 8414.5, 12577.0, and 16804.5 kHz. Distress, Safety, Urgency DSC calls. Distress, Safety, Urgency and Routine DSC Calls. Routine DSC Call. OptionDSC calls are roughly divided in two groups: distress messages and general (safety,Below are the types of DSC messages. CallYour ship sends distress message. Your ship relays distress call to all ships in a specific geographical area. Your ship relays distress call to a coast station. Inform areas that your ship is carrying medical supplies.

    Inform areas that your ship is not a participant in armed conflict. Call to a specific address. Call over Public Switched Telephone Network (PSTN). Send test signal to a station to test your station's functionality. Call to a specific group. Call to all ships in a specific geographical area. Your ship requests position of other ships. Confirm if your ship is within communicating range with other ships. (Receive and answer only)Call category. CallCoast station ID begins with 00; Group ID begins with 0. Distress: Grave and imminent danger and request immediate assistance. Urgency: A calling station has a very urgent call to transmit concerning safety ofSafety: A station is about to transmit a call containing an important navigational orRoutine: General calling. TELEPHONE: Telephone (J3E) by SSB radiotelephone. Working frequency used to call by telephone or NBDP. The sending station mayPosition can be automatically or manually set. DSC frequency to use. If the call priority is SAFETY, URGENCY or DISTRESS, select a DSC distress frequency.When you receive a distress alert or general call addressed to your ship, the audio andThe audio alarm can be silenced with the CANCEL key. AlarmSafety call receivedRoutine call receivedWhile DISTRESS key is pressed for fourDistress alert sentOwn ship position not updatedDistress alert call receivedDistress relay call receivedDistress relay ack call receivedDistress ack call receivedUrgency call receivedUrgency ack call receivedDescription of Call Screens. This section provides the information necessary for interpreting the receive and sendBelow are sample distress alert and individual RX call screens. The contents of otherDistress alert. Speaker icon. Call type. ID No. (MMSI)Nature of distress. CommunicationRF gain. Working frequencyElapsed time sinceDistance to shipPosition of shipDSC frequency. Available user options. Session in progress. Individual RX call. ID No. (MMSI)CommunicationRF gainElapsed time sinceCommunication mode.

    Creator: Adobe Illustrator CS3. Modify Date: 2012:08:28 07:40:58-07:00. Has XFA: No. Metadata Date: 2012:08:28 07:40:58-07:00. Creator Tool: Adobe Illustrator CS3. Document ID: uuid:24d79021-8279-466e-92d6-bfaf7d0b13a2. Instance ID: uuid:ccbac96f-676b-4603-9b37-ea324004b772. Producer: Adobe PDF library 8.00. Page Count: 44. Refer to its operator's manual for oper- ation. 7.2 Description of Equipment 7.2.1 Terminal unit The terminal unit is a visual display incorporating a floppy disk drive (for IB-583) or an SD card drive (IB-585). To adjust the brilliance, press the Alt key while pressing the F6 key to lower the brilliance; the F7 key to raise it. 8 levels of brilliance are available for IB-583 and 11 levels for IB-585. When the terminal unit is turned on, the communication status screen, shown on the next page, appears. This is where all phases of telex communications begin. TERMINAL UNIT IB-583 Power switch Floppy disk drive PRINTER PP-510 Power switch TERMINAL UNIT IB-585 Power switch SD card drive The power switch backlights for IB-583 and IB-585 light in green during power-on. USB connector (Connect the keyboard here.) Prev Next. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Start Free Trial Cancel anytime. Furuno SSB Operator's Manual.pdf Uploaded by andersonpauser 100% (1) 100% found this document useful (1 vote) 615 views 222 pages Document Information click to expand document information Description: Furuno SSB Operator's Manual.pdf - Manual operacional do Furuno SSB.Browse Books Site Directory Site Language: English Change Language English Change Language. Data is displayed on a large, easy-to-read backlit LCD. Operation is simplified by the use of few keys and easy-to-follow menus. Page Count: 84 SYSTEM CONFIGURATION.ii. EQUIPMENT LIST. iiiAll brand and product names are trademarks, registered trademarks or service marks of their respective holders.Nishinomiya, 662?8580, JAPAN.

    Printed in JapanConfirm that the power supply voltageElectrical shock, serious injuryConnection to the wrong power supplyGround the equipment.Do not touch duringDo not touch the whipHandle copper strap carefully. An edge of it may harm your hand. Electrical shock, seriousKeep the following compass safeDo not work inside theTransceiver UnitTurn off the power at thePost a sign near the switchFire, electrical shock orSwitch AS-102Category. Exposed to weather. Preamp Unit. Antenna Coupler Exposed to weather. Protected from weather. Other UnitsName. Type. Code no. Qty. Remarks.